SmartVolt™ · Rechargeable · Dual ToneSmartVolt™ Rechargeable v2.0

JSVR-DT

The latest SmartVolt: smaller, 50 g, and 200 hours on a one-hour USB-C charge. SmartVolt warns a worker the moment they come within range of a live AC conductor, from 220 V up to 66 kV, without contact.

SmartVolt™ Rechargeable v2.0 non-contact voltage detector, grey top, black base
220 V – 66 kVAC detection range
2.5 mAlarm distance at 66 kV
50 gWeight
200 hPer charge
IP55Ingress protection
SmartPause™Auto re-arm
Overview

A wearable early warning for every live line

SmartVolt worn by a lineman at work
SmartVolt in the field

Why crews wear it

Most electrical contact incidents happen to people who believed a line was dead, or who did not notice one nearby. SmartVolt gives them a second sense: a loud, visible warning before their hands get there.

  • Detects live AC from 220 V to 66 kV without contact
  • Alarm: sound (buzzer) and light (red led)
  • SmartPause™ silences the alarm in a known live zone, then re-arms itself
  • 50 g, 61 × 48.9 × 32.15 mm
  • Up to 200 hours (varies with use), full charge in 1 hour over USB Type-C
  • Helmet, wrist and PPE mounting
  • IP55: dust and water jets from any direction
How it works

Switch on, test, clip on, get warned.

Switch on

Press the red button on top. The three LEDs show battery level, and the green and red LEDs underneath light up to confirm the alarms work.

Test at a socket

Hold it near a live 220 V socket before every shift. It should beep and flash red. That proves it is detecting.

Mount it

Clip it to the helmet, wrist or PPE using the supplied mounts. The green LED blinks every 5 seconds to show it is on watch.

Work. It warns.

Come within range of a live AC field and it beeps with a red LED alert, before you can reach the conductor.

SmartPause™. When a worker deliberately enters a known danger zone, one press silences the alarm. SmartVolt re-arms itself automatically once they move out of the field, and can also be re-armed by hand. No one has to remember to switch it back on.

Detection

Alarm distance grows with voltage

Detection distance by AC voltage

Detection distance by AC voltage
AC voltageDistance (m)
220 V0.15
1 kV1.1
6.6 kV1.7
11 kV1.9
33 kV2.2
66 kV2.5

Distances at which the alarm triggers, per the SmartVolt technical data sheets. Treat them as typical values. The actual distance depends on conductor geometry and surroundings.

Room to stop

At 11 kV the alarm sounds at about 1.9 m; at 66 kV, about 2.5 m. That is far enough to stop, step back and check.

An early warning, not a permit to work. Non-contact detection tells a worker that a live field is near. It does not prove a conductor is dead. Keep isolating, testing with an approved contact tester and earthing before any work on a line, exactly as your safety rules require.

Features

Everything it does, and nothing that gets in the way

Non-contact detection

Senses the electric field around live AC conductors from 220 V to 66 kV.

220 V – 66 kV AC

Alarm you notice

Audible buzzer together with a red LED alert.

Sound (buzzer) and light (red LED)

SmartPause™

Silence the alarm while deliberately working in a known live zone. It re-arms automatically on exit, or by hand.

Auto re-arm

Always-on indicator

Green LED blinks every 5 seconds so the worker and supervisor can see it is armed.

Blink every 5 s

Battery warnings

Three-level battery indicator. The red LED blinks at 20 %; it beeps below 5 %.

3-level indicator

Rechargeable, USB Type-C

Internal 600 mAh battery charges fully in 1 hour. Up to 200 hours (varies with use).

200 h
In the box

Ready to wear out of the box

SmartVolt with its helmet clip, PPE clip and wrist band
  • 01
    SmartVolt™ unitJSVR-DT
  • 02
    Helmet mount
  • 03
    Wrist band
  • 04
    Side / PPE clip

Supplied with three mounting attachments (helmet, wrist, PPE). Confirm the exact kit with our team when ordering.

SmartVolt JSVR-DT side view showing the USB Type-C charging port
USB Type-C charging port
Technical data

Specifications

SmartVolt™ Rechargeable v2.0JSVR-DT

Detection

Type
Non-contact, AC voltage
Range
220 V – 66 kV AC
Distance
220 V 0.15 m · 1 kV 1.1 m · 6.6 kV 1.7 m · 11 kV 1.9 m · 33 kV 2.2 m · 66 kV 2.5 m
Alerts
Sound (buzzer) and light (red LED)
SmartPause™
Temporary silence; automatic or manual re-arm
Status indication
Green LED blinks every 5 s when on

Physical

Dimensions
61 × 48.9 × 32.15 mm
Weight
50 g
Material
ABS plastic
Housing finish
Dual Tone (grey top, black base)

Power

Power source
Internal battery, 600 mAh
Charging
Rechargeable over USB Type-C, 5 V input
Charging time
1 hour
Runtime
Up to 200 hours (varies with use)
Low battery
Red LED blinks below 20 %; beeps below 5 %

Environment

Operating temperature
10 °C to 50 °C
Storage temperature
−20 °C to 60 °C
Ingress protection
IP55: protected against dust and water jets from any direction; do not submerge

Mounting

Options
Helmet, wrist, PPE

Specifications per Jarsh TDS JSVR-DT V0.2 · 05.2026. IP55 per the Jarsh Smart Safety Catalogue (09.2026).

Compare

How it compares with other SmartVolt models

All SmartVolt models →
JSVR-DTRechargeable v2.0JSV-DTCDual Tone · AAAJSV-MTCMono Tone · AAA
Detection
AC voltage range220 V – 66 kV220 V – 66 kV220 V – 66 kV
Alarm distance at 66 kV2.5 m2.5 m2.5 m
AlertsSound (buzzer) and light (red LED)Sound (buzzer) and light (red LED)Sound (buzzer) and light (red LED)
SmartPause™ auto re-arm
Power
Power source600 mAh rechargeableAAA cells, swappableAAA cells, swappable
Runtime (varies with use)200 h150 h150 h
Charge time1 hourNo chargingNo charging
Build
Weight50 g70 g70 g
Dimensions61 × 48.9 × 32.15 mm62 × 60 × 35 mm62 × 60 × 35 mm
Ingress protectionIP55IP55IP55
HousingDual ToneDual ToneMono Tone
Tested and certified by—NTH Kolkata · ERDANTH Kolkata · ERDA
View →View →View →
Use and care

Safe use, every shift

Before and during work

  • Switch on and confirm the green and red LEDs light
  • Test near a live 220 V socket before use
  • Mount securely on helmet, wrist or PPE so it cannot detach
  • Use SmartPause™ with care, and make sure it has re-armed after leaving a live zone

Looking after it

  • Check the battery level regularly; recharge when the red LED blinks
  • Charge over USB Type-C, 1 hour for a full charge
  • Protected against dust and water jets where IP55-rated; never submerge
  • Operate between 10 °C and 50 °C

An early warning, not a permit to work. Non-contact detection tells a worker that a live field is near. It does not prove a conductor is dead. Keep isolating, testing with an approved contact tester and earthing before any work on a line, exactly as your safety rules require.

Proof from the field

Chosen over the incumbent after a 45‑day trial

“The SmartVolt fundamentally changed how our Electrical Maintenance Engineer teams approach preliminary checks. We no longer had to risk contact or rely on complicated procedures for a simple ‘live or dead’ confirmation.”
Network Maintenance Engineer, leading Indian internet service provider, Hyderabad
5,000+Field workforce at a leading ISP laying cable on utility poles
45 daysReal-world evaluation against the incumbent detector
Outperformedon accuracy, durability, responsiveness and ease of use
Read the case study →
FAQ

Common questions

Can't find what you need? Call +91 8340 84 84 84 or write to info@jarshsafety.com.

What voltage does SmartVolt detect?
AC voltage from 220 V up to 66 kV, without contact. The higher the voltage, the earlier it warns: about 0.15 m from a 220 V source and about 2.5 m from a 66 kV line.
Does SmartVolt detect DC?
No. SmartVolt is specified for AC voltage only.
Is SmartVolt a replacement for a contact voltage tester or earthing?
No. It is a wearable early warning that a live field is near. Keep following isolation, contact-testing and earthing procedures before work on any line.
What is the difference between Mono Tone and Dual Tone?
The housing finish. Mono Tone is all grey; Dual Tone has a grey top and a black base. Detection range, distances and alarms are identical.
What does SmartPause™ do?
It lets a worker silence the alarm while deliberately working in a known live zone. The device re-arms automatically once they leave the field, or can be re-armed by pressing the button.
How long does a charge last?
Up to 200 hours (varies with use). A full charge takes 1 hour. The red LED starts blinking at 20 % battery, and it beeps below 5 %.
How do I know it is working?
On switch-on, the green and red LEDs underneath light up. In use, the green LED blinks every 5 seconds. Test it near a live 220 V socket before each shift. It should beep and flash red.
Can it be used in the rain?
All three SmartVolt models are rated IP55: protected against dust and against water jets from any direction. Do not submerge them in water.
What temperature range does it work in?
Operating 10 °C to 50 °C; storage −20 °C to 60 °C.
Where can it be worn?
On the helmet, the wrist or the PPE, using the clips and wrist band supplied. Mount it securely so it cannot detach.
Do you supply in bulk and through dealers?
Yes. For volume pricing, utility and contractor programmes, or to become a SmartVolt dealer, contact our team.

Get SmartVolt™ Rechargeable v2.0 for your crews.

Tell us how many workers need cover and where they work. We'll quote, arrange a demo and advise on mounting.

Partner Login