Portable Ventilation & Cooling · General-purpose blowerIndustrial Blower CE Move the air, not the crew.

JIB-CE-300

A 300 mm portable axial blower for workshops, confined spaces and general industrial ventilation.

Jarsh JIB-CE-300 industrial blower in orange, front view with fan guard
65 m³/minAirflow
373 PaStatic pressure
520 WMotor power
220/240 VSingle-phase, 50/60 Hz
Where it's used

Ventilation wherever the air goes stale

A general-purpose blower for non-hazardous industrial ventilation.

Workshops & fabrication bays

Clear hot or stale air from work areas and bring fresh air to the bench.

Supply or exhaust

Confined spaces

Ventilate manholes, chambers and tanks with non-flammable atmospheres before and during entry.

Duct to the point of work

Plant rooms & basements

Move air through areas with no fixed ventilation.

Portable

Hot work areas

Push cooler air toward crews working near heat sources.

Spot cooling

Flammable gas or vapour present? Use the ATEX Industrial Blower instead. This blower is not explosion-protected.

Features

What it does, with the numbers

Side view of the orange Jarsh CE industrial blower with its black carry handle
At a glance
65 m³/minAirflow
373 PaStatic pressure
520 WMotor power
CEMarked
  • High airflow: 65 m³/min at 373 Pa from a 520 W motor, so it pushes air down a 10 m duct.
  • 16-gauge steel housing: Steel shell, epoxy powder coated against corrosion and wear.
  • Flanged both ends: Fit the duct to the intake to extract, or to the outlet to supply fresh air.
  • Easy to move: Integrated carry handle; four rubber feet keep it steady and cut vibration.

High airflow

65 m³/min at 373 Pa from a 520 W motor, so it pushes air down a 10 m duct.

65 m³/min

16-gauge steel housing

Steel shell, epoxy powder coated against corrosion and wear.

Built tough

Flanged both ends

Fit the duct to the intake to extract, or to the outlet to supply fresh air.

Supply or exhaust

Easy to move

Integrated carry handle; four rubber feet keep it steady and cut vibration.

Portable

Protective grill

Metal-coated grill guards the blades on both faces.

Guarded

Continuous duty

Aerodynamic fan and housing designed for long industrial runs.

All-shift
Fan guard and blades of the CE blower
CE blower at an angle with its power cable
Carry handle and ON/OFF switch of the CE blower
Black retractable PVC ventilation duct
Duct

Pair it with the PVC Ventilation Duct

Ducting turns a blower into targeted ventilation: fresh air to the point of work, or stale air out of it.

Black retractable PVC ventilation duct
JIB-CE-300_DUCT

PVC Ventilation Duct

Lightweight, retractable PVC-coated duct for the CE blower in non-hazardous areas.

Lengths
10 m standard · 15 m on request
Diameter
300 mm (12″)
Material
Vinyl and polyester, PVC-coated, single ply
Wire helix
Class 1 hard-drawn spring steel
Seams
Heat-sealed for a smooth bore
Temperature
−28.8 to 82.2 °C
Airflow
Supply or exhaust; couple ducts for longer runs
Non-collapsibleLow friction loss

Fitting the duct

  • 1 · Position the duct cuff over the blower flange with the rope loosened
  • 2 · Tighten the rope for a firm, leak-free fit
  • 3 · Run the duct to the point of work; couple a second duct for longer runs

Keep the duct as straight as you can. Every bend and every extra metre reduces airflow at the far end.

Specifications

Full technical specifications

Per the current Jarsh technical data sheet.

Industrial Blower CEJIB-CE-300

Performance

Airflow
65 m³/min
Static pressure
373 Pa
Motor power
520 W
Fan speed
2800 / 3300 r/min
Supply
220 / 240 V AC, 50 / 60 Hz, single phase

Construction

Housing
16-gauge steel
Finish
Orange epoxy powder coat
Grill
Metal-coated protective grill
Handling
Integrated carry handle, 4 rubber feet
Duty
Continuous industrial use

Dimensions & compliance

Fan diameter
300 mm (12″)
Unit size
320 × 400 × 400 mm
Compliance
CE marked
Hazardous areas
Not rated. Use the ATEX blower

Source: Jarsh JIB-CE-300 TDS (V0.2 12.2025) and the Jarsh blower manual.

Operation & care

Safe set-up, every time

Operating

  1. Check that the supply voltage matches the rating on the nameplate.
  2. Place the blower on a flat, stable surface, clear of obstructions and combustible materials.
  3. Fit the duct to the intake or outlet flange.
  4. Connect to a properly earthed socket. Electrical connection by a qualified electrician.
  5. Switch on and let the blower reach full speed before loading the airflow.

Safety & maintenance

  • Not for flammable gas or vapour atmospheres
  • Keep hands and tools away from the blades; disconnect power before any maintenance
  • Never modify the electrical parts or wiring; don't use damaged cables or plugs
  • Inspect before every use; clean with compressed air, not water or solvents
  • Have the electrics inspected every six months, or more often in hard use
  • After use, switch off, unplug, let it cool, and store dry; carry it by the handle
Compare

ATEX or CE: which blower do you need?

Same size, same airflow at 50 Hz. The difference is where you can use it.

JIB-CE-300Industrial Blower CEJIB-AtEx-300ATEX Industrial Blower
Where to useNon-hazardous areasZone 1 & 2 gas areas, IIB, T4
Airflow65 m³/min65 m³/min (50 Hz) · 75 m³/min (60 Hz)
Static pressure373 Pa373 Pa
Motor power520 W520 W
Supply220/240 V, 50/60 Hz220 V (110 V optional), 50/60 Hz
Fan diameter300 mm (12″)300 mm (12″)
Unit size320 × 400 × 400 mm440 × 400 × 400 mm
Weight—17 kg
DuctPVC, 10 m (15 m on request)Antistatic, earthed, 10 m (15 m on request)
ComplianceCE markedATEX; marking and certificate with quote
This pageView →
FAQ

Common questions

Still unsure? Ask us: we reply within 24 hours.

Can the CE blower be used in a hazardous area?
No. It is not explosion-protected. For Zone 1 or 2 gas areas, use the ATEX Industrial Blower with its antistatic duct.
Can it ventilate a confined space?
Yes, where the atmosphere is not flammable. Push fresh air in through the duct or pull stale air out. Ventilation doesn't replace gas testing, a permit or a standby person.
How is the CE blower different from the ATEX blower?
Same 300 mm size, 520 W motor and 65 m³/min airflow at 50 Hz. The ATEX blower adds explosion protection for Zone 1 and 2 gas areas, a heavier 17 kg build and an antistatic duct. The CE blower is lighter and costs less for non-hazardous work.
What power does it need?
A standard single-phase 220/240 V, 50/60 Hz supply from a properly earthed socket.
Do you supply in bulk and work with dealers?
Yes. For site kits and volume orders, request a quote. To stock Jarsh blowers, apply to become a dealer.

Get a quote for the Industrial Blower CE.

Tell us the quantity, duct length and where you'll use it. We reply within 24 hours with pricing, lead time and the data sheet.

Our team replies within 24 hours.

Partner Login