Portable Ventilation & Cooling · Hazardous-area blowerATEX Industrial Blower Fresh air, even in a gas zone.

JIB-AtEx-300

A 300 mm explosion-protected axial blower for Zone 1 and Zone 2 gas areas, group IIB, T4.

Jarsh JIB-AtEx-300 ATEX industrial blower in orange with explosion-protected switch housing
65 / 75 m³/minAirflow at 50 / 60 Hz
373 PaStatic pressure
520 WMotor power
Zone 1 & 2Gas group IIB · T4
Where to use it

Check your zone before you order

The blower is protected for gas atmospheres in Zone 1 and Zone 2, gas group IIB, temperature class T4.

Use it

Zone 1 and Zone 2, gas

Areas where a flammable gas or vapour atmosphere is likely (Zone 1) or occasional (Zone 2): tank and vessel entry, pump rooms, process units, loading bays.

Gas groups

IIA and IIB · T4

Propane, methane, petrol vapour, ethylene and most solvents. T4 means surface temperatures stay at or below 135 °C.

Don't use it

IIC gases, dust, Zone 0

Not for hydrogen, acetylene or carbon disulphide (group IIC), combustible-dust zones, or Zone 0. Ask us before using it where these may be present.

Hazardous areas: The ATEX blower ships with its Ex marking and certificate. We send both with your quotation so you can check them against your hazardous-area classification before you order. Ask for the documents →

Features

What it does, with the numbers

Side view of the Jarsh ATEX blower showing its flameproof switch box and carry handle
At a glance
65 m³/minAirflow, 50 Hz
373 PaStatic pressure
IIB · T4Zone 1 & 2 gas
17 kgWeight
  • Explosion-protected axial fan: Motor and switch enclosed for Zone 1 and 2 gas areas, with a rotary 0/1 switch on the housing.
  • 16-gauge steel housing: Carbon-steel shell, epoxy powder coated against corrosion and wear.
  • Flanged both ends: Fit the duct to the intake to extract, or to the outlet to supply fresh air.
  • Easy to move: Integrated carry handle; four rubber feet keep it steady and cut vibration.

Explosion-protected axial fan

Motor and switch enclosed for Zone 1 and 2 gas areas, with a rotary 0/1 switch on the housing.

IIB · T4

16-gauge steel housing

Carbon-steel shell, epoxy powder coated against corrosion and wear.

Built tough

Flanged both ends

Fit the duct to the intake to extract, or to the outlet to supply fresh air.

Supply or exhaust

Easy to move

Integrated carry handle; four rubber feet keep it steady and cut vibration.

17 kg

Protective grill

Metal-coated grill guards the blades on both faces.

Guarded

Continuous duty

Aerodynamic fan and housing designed for long industrial runs.

All-shift
Front grill and fan of the ATEX blower
Explosion-protected rotary ON/OFF switch, 0 and 1 positions
Intake grill with Jarsh logo on the hub
Antistatic duct coil with red grounding clamps at each end
Duct

Pair it with the Antistatic ATEX Duct

In a hazardous area, use only the antistatic duct: it carries static charge to earth instead of letting it spark.

Coiled antistatic ATEX duct with red grounding clamps on its earthing wires
JIB-AtEx-300_DUCT

Antistatic ATEX Duct

Retractable, flame-retardant, neoprene-coated duct for hazardous and static-sensitive areas, earthed at both ends.

Lengths
10 m standard · 15 m on request
Diameter
300 mm (12″)
Material
Vinyl and polyester, antistatic, neoprene-coated, single ply
Antistatic rating
≤ 100,000 Ω per sq in
Earthing
Solid grounding wire at each end
Wire helix
Class 1 hard-drawn spring steel
Temperature
−53 to 121 °C
Airflow
Supply or exhaust; couple ducts for longer runs
AntistaticFlame retardantNon-collapsible

Fitting the duct

Step 1: open the cover at the end of the duct
Step 2: loosen the rope and position the duct over the outlet
Step 3: tighten the rope for a firm, leak-free fit
  • 1 · Open the cover at the end of the duct
  • 2 · Position the duct over the flange with the rope loosened
  • 3 · Tighten the rope for a firm, leak-free fit, then clip the grounding wires to earth at both ends
Specifications

Full technical specifications

Per the current Jarsh technical data sheet.

ATEX Industrial BlowerJIB-AtEx-300

Performance

Airflow
65 m³/min at 50 Hz · 75 m³/min at 60 Hz
Static pressure
373 Pa
Motor power
520 W
Fan speed
2800 / 3300 r/min
Noise
71 dB(A)
Supply
220 V AC standard, 110 V optional · 50/60 Hz

Hazardous area

Use
Zone 1 and Zone 2, gas atmospheres
Gas group
IIB (also covers IIA)
Temperature class
T4 (≤ 135 °C)
Ex marking & certificate
Supplied with the quotation

Construction

Housing
16-gauge carbon steel
Finish
Epoxy powder coat, corrosion and wear resistant
Grill
Silver metal-coated
Duct ends
Flanged, intake or exhaust
Handling
Carry handle, 4 rubber feet

Dimensions

Fan diameter
300 mm (12″)
Unit size
440 × 400 × 400 mm
Weight
17 kg

Source: Jarsh JIB-AtEx-300 TDS and the Jarsh blower manual. Supply voltage per the TDS model table and manual.

Sizes

Need more air? The ATEX range runs to 600 mm

All eight sizes share the same explosion-protected design.

ModelSizePower (W)Speed (r/min)Airflow (m³/min)Static pressure (Pa)Noise dB(A)
JIB-AtEx-200200 mm (8″)2302800 / 330025 / 3524560
JIB-AtEx-250250 mm (10″)3202800 / 330043 / 5329468
JIB-AtEx-300300 mm (12″)5202800 / 330065 / 7537371
JIB-AtEx-350350 mm (14″)7502800 / 330082 / 9059876
JIB-AtEx-400400 mm (16″)1,1002800 / 33009670080
JIB-AtEx-450450 mm (18″)750145016022478
JIB-AtEx-500500 mm (20″)1,100145016627084
JIB-AtEx-600600 mm (24″)2,200145029030090

The JIB-AtEx-300 is the standard model. The other sizes are supplied on request. Two values mean 50 Hz / 60 Hz; all models run on 220/110 V. Ask for another size →

Operation & care

Safe set-up, every time

Operating

  1. Check that the supply voltage matches the rating on the nameplate.
  2. Place the blower on a flat, stable surface, clear of obstructions.
  3. Fit the duct to the intake or outlet flange, and earth both grounding wires.
  4. Connect to a properly earthed socket. Electrical connection by a qualified electrician.
  5. Switch on and let the blower reach full speed before loading the airflow.

Safety & maintenance

  • Use only inside the certification limits: Zone 1 or 2, gas group IIB, T4
  • Keep hands and tools away from the blades; disconnect power before any maintenance
  • Never modify the electrical parts or wiring; don't use damaged cables or plugs
  • Inspect before every use; clean with compressed air, not water or solvents
  • Have the electrics inspected every six months, or more often in hard use
  • After use, switch off, unplug, let it cool, and store dry; carry it by the handle
Compare

ATEX or CE: which blower do you need?

Same size, same airflow at 50 Hz. The difference is where you can use it.

JIB-CE-300Industrial Blower CEJIB-AtEx-300ATEX Industrial Blower
Where to useNon-hazardous areasZone 1 & 2 gas areas, IIB, T4
Airflow65 m³/min65 m³/min (50 Hz) · 75 m³/min (60 Hz)
Static pressure373 Pa373 Pa
Motor power520 W520 W
Supply220/240 V, 50/60 Hz220 V (110 V optional), 50/60 Hz
Fan diameter300 mm (12″)300 mm (12″)
Unit size320 × 400 × 400 mm440 × 400 × 400 mm
Weight—17 kg
DuctPVC, 10 m (15 m on request)Antistatic, earthed, 10 m (15 m on request)
ComplianceCE markedATEX; marking and certificate with quote
View →This page
FAQ

Common questions

Still unsure? Ask us: we reply within 24 hours.

Which hazardous areas can it be used in?
Zone 1 and Zone 2 gas atmospheres in gas group IIB (which also covers IIA), temperature class T4. It is not rated for group IIC gases such as hydrogen or acetylene, or for combustible-dust zones. Always check the Ex marking we send with your quote against your area classification.
Why does the duct need to be antistatic?
Air moving through a plastic duct builds up static charge, and a spark can ignite a flammable atmosphere. The JIB-AtEx-300_DUCT is rated at 100,000 Ω or less per square inch and has a solid grounding wire at each end, so you can earth it to the blower and the structure.
Can I use a standard PVC duct with the ATEX blower?
No. In a hazardous area, use only the antistatic duct. The PVC duct is for the CE blower in non-hazardous areas.
Is a bigger or smaller ATEX blower available?
Yes. The ATEX range runs from 200 mm to 600 mm (25 to 290 m³/min). The 300 mm JIB-AtEx-300 is the standard model; ask us for the other sizes.
Can it supply air into a tank and extract from one?
Yes. Fit the duct to the intake to pull air out, or to the outlet to push fresh air in. The duct handles both directions.
Do you supply in bulk and work with dealers?
Yes. For site kits and volume orders, request a quote. To stock Jarsh blowers, apply to become a dealer.

Get a quote for the ATEX Industrial Blower.

Tell us the quantity, duct length and where you'll use it. We reply within 24 hours with pricing, lead time and the data sheet, plus the Ex marking and certificate.

Our team replies within 24 hours.

Partner Login